UPS Wadi Tower 6–10 kVA

Single-phase online tower UPS (6–10 kVA) with DSP control, PFC 0.99, high efficiency, and strong overload capability.

somdn_product_page

Categories: ,

Overview

Single-phase online UPS 6–10kVA models from Wadi Tower provide reliable power protection for critical commercial, industrial and enterprise applications.

The series includes 6kVA and 10kVA models. Both models provide equal kVA and kW output capacity through a unity output power factor of 1.0.

True Double-Conversion Protection

Wadi Tower uses true double-conversion online technology to isolate connected equipment from common power disturbances. It provides zero transfer time from AC mode to battery mode and delivers pure sine wave output.

Advanced DSP control and active power factor correction support stable and efficient operation. The UPS provides an input power factor of 0.99 at full load.

Single-Phase Online UPS 6–10kVA Features

  • Available in 6kVA and 10kVA models.
  • Single-phase input and single-phase output.
  • True double-conversion online topology.
  • Unity output power factor of 1.0.
  • Zero transfer time to battery operation.
  • Pure sine wave output.
  • Advanced DSP control.
  • Active Power Factor Correction.
  • Input power factor of 0.99 at full load.
  • AC mode efficiency of up to 95%.
  • Output voltage selectable at 208V, 220V, 230V or 240V.
  • ECO mode.
  • Emergency Power Off function.
  • Support for 50Hz and 60Hz frequency conversion.
  • Standard and long-run battery configurations.
  • Adjustable battery quantity from 16 to 20 batteries.
  • Adjustable charging current for long-run models.
  • RS-232 and USB communication.
  • Optional SNMP network management.

Applications

The Wadi Tower single-phase online UPS 6–10kVA range is suitable for:

  • Server rooms and network equipment.
  • Data and communication systems.
  • Medical and laboratory equipment.
  • Industrial control systems.
  • Security and surveillance systems.
  • Banks and financial institutions.
  • Commercial and enterprise equipment.
  • Other critical single-phase loads.

Selecting the Correct UPS

The correct UPS capacity depends on the total connected load, equipment power factor, starting current, required backup time and future expansion.

The battery configuration should be selected according to the required operating time. Loads with motors, transformers or high starting currents require additional technical review.

Additional Product Information

For technical documents and product information, visit the PowerWadi Download Center:

https://powerwadi.com/download-center/

Request a Quote

Send your load schedule, required backup time, preferred battery configuration and site information to PowerWadi. Our technical team will help you select the correct Wadi Tower model for your application.